We ship from multiple warehouses throughout the USA
to get you what you need as fast as possible!
Millions of items in stock!
Fast online checkout - No account required
Cart 0

Lighting & Electrical > Contactors & Starters (ET04) - (4030 Products)


Lighting & Electrical > Contactors & Starters (ET04)

Schneider Electric - Contactor Red Auxiliary Contact Block - For Use with Size 00-2 Contactors and Size 00-2 Starters


Item #: 49754039
Brand: Schneider Electric
Model #: LADN22S
Exact Tooling IR#: 04

Product Specifications
Contactor Accessory Type Red Auxiliary Contact Block
For Use With Size 00-2 Contactors; Size 00-2 Starters

$60.65

2% Off All Online Orders
Use Code: 2%OFF

Best Price Guarantee - Email Us A Better Published Price and We'll Beat It

Square D - Contactor Thermal Unit - For Use with C Series


Item #: 54422258
Brand: Square D
Model #: CC50.1
Exact Tooling IR#: 04

Product Specifications
Contactor Accessory Type Thermal Unit
For Use With C Series

$42.08

2% Off All Online Orders
Use Code: 2%OFF

Best Price Guarantee - Email Us A Better Published Price and We'll Beat It

Square D - 110 Coil VAC at 50 Hz, 120 Coil VAC at 60 Hz, 18 Amp, Reversible Enclosed Enclosure NEMA Motor Starter - 3 Phase hp: 3 at 200 VAC, 3 at 230 VAC, 5 at 460 VAC, 5 at 575 VAC, 12 Enclosure Rating


Item #: 56824634
Brand: Square D
Model #: 8736SBA4V02S
Exact Tooling IR#: 04

Features and Benefits

Enclosed housings are designed to ensure that the motor is never disconnected from power during starting. Ideal for frictional loads and prevention of electrical shocks and dust.
Reversing starters are designed with three individual lines that connect to and run voltage through a motor. Each line alternates in a sequence as they reach their voltage peak. They are used to reverse the rotation of a motor.
NEMA 12 refers to enclosures constructed (without knockouts) for indoor use. They provide a degree of protection from falling dirt, circulating dust, lint, fibers, flyings, water dripping and light splashing.
Product Specifications
Amperage 18
NEMA Size 0
Coil Voltage 110 VAC @ 50 Hz; 120 VAC @ 60 Hz
Enclosure Type Enclosed
Action Reversible
NEMA Enclosure Rating 12
Horsepower at 3 Phase 3 @ 200 VAC; 3 @ 230 VAC; 5 @ 460 VAC; 5 @ 575 VAC
Standards Met CSA; NEMA; RoHS Compliant; UL Listed

$2,142.52

2% Off All Online Orders
Use Code: 2%OFF

Best Price Guarantee - Email Us A Better Published Price and We'll Beat It

Square D - 220 Coil VAC at 50 Hz, 240 Coil VAC at 60 Hz, 9 Amp, Nonreversible Enclosed Enclosure NEMA Motor Starter - 3 Phase hp: 1-1/2 at 200 VAC, 1-1/2 at 230 VAC, 2 at 460 VAC, 2 at 575 VAC, 1 Enclosure Rating


Item #: 54421508
Brand: Square D
Model #: 8536SAG12V03
Exact Tooling IR#: 04

Features and Benefits

Enclosed housings are designed to ensure that the motor is never disconnected from power during starting. Ideal for frictional loads and prevention of electrical shocks and dust.
Non-reversing starters are designed with one phase line that connects to and runs voltage through the motor. The starter is used to turn a motor on and off.
NEMA 1 refers to enclosures constructed for indoor use. They provide a degree of protection from falling and other solid objects entering the enclosure.
Product Specifications
Amperage 9
NEMA Size 00
Coil Voltage 220 VAC @ 50 Hz; 240 VAC @ 60 Hz
Enclosure Type Enclosed
Action NonReversible
NEMA Enclosure Rating 1
Horsepower at 3 Phase 1-1/2 @ 200 VAC; 1-1/2 @ 230 VAC; 2 @ 460 VAC; 2 @ 575 VAC
Standards Met CSA; RoHS Compliant; UL Listed

$447.34

2% Off All Online Orders
Use Code: 2%OFF

Best Price Guarantee - Email Us A Better Published Price and We'll Beat It

Square D - 220 Coil VAC at 50 Hz, 240 Coil VAC at 60 Hz, 27 Amp, NEMA Size 1, Nonreversible Enclosed Enclosure NEMA Motor Starter - 3 Phase hp: 10 at 460 VAC, 10 at 575 VAC, 7-1/2 at 200 VAC, 7-1/2 at 230 VAC, 1 Enclosure Rating


Item #: 56815426
Brand: Square D
Model #: 8536SCG3V03A
Exact Tooling IR#: 04

Features and Benefits

Enclosed housings are designed to ensure that the motor is never disconnected from power during starting. Ideal for frictional loads and prevention of electrical shocks and dust.
Non-reversing starters are designed with one phase line that connects to and runs voltage through the motor. The starter is used to turn a motor on and off.
NEMA 1 refers to enclosures constructed for indoor use. They provide a degree of protection from falling and other solid objects entering the enclosure.
Product Specifications
Amperage 27
NEMA Size 1
Coil Voltage 220 VAC @ 50 Hz; 240 VAC @ 60 Hz
Enclosure Type Enclosed
Action NonReversible
NEMA Enclosure Rating 1
Horsepower at 3 Phase 10 @ 460 VAC; 10 @ 575 VAC; 7-1/2 @ 200 VAC; 7-1/2 @ 230 VAC
Standards Met CSA; NEMA; RoHS Compliant; UL Listed

$1,202.88

2% Off All Online Orders
Use Code: 2%OFF

Best Price Guarantee - Email Us A Better Published Price and We'll Beat It

Square D - 208 Coil VAC at 60 Hz, 90 Amp, NEMA Size 3, Nonreversible Open Enclosure NEMA Motor Starter - 3 Phase hp: 25 at 200 VAC, 30 at 230 VAC, 50 at 460 VAC, 50 at 575 VAC


Item #: 56813942
Brand: Square D
Model #: 8536SEO1V08H30
Exact Tooling IR#: 04

Features and Benefits

Open housings are designed to disconnect the motor from the line at the time of starting or stopping of equipment. Ideal for inertial loads and they are finger safe.
Non-reversing starters are designed with one phase line that connects to and runs voltage through the motor. The starter is used to turn a motor on and off.
Open - no enclosures are starters without a protective enclosure.
Product Specifications
Amperage 90
NEMA Size 3
Coil Voltage 208 VAC @ 60 Hz
Enclosure Type Open
Action NonReversible
NEMA Enclosure Rating Open - No Enclosure
Horsepower at 3 Phase 25 @ 200 VAC; 30 @ 230 VAC; 50 @ 460 VAC; 50 @ 575 VAC
Standards Met CSA; NEMA; UL Listed

$1,701.66

2% Off All Online Orders
Use Code: 2%OFF

Best Price Guarantee - Email Us A Better Published Price and We'll Beat It

Square D - 90 Amp, NEMA Size 3, Open Enclosure NEMA Motor Starter


Item #: 56813926
Brand: Square D
Model #: 8536SEO6V02S
Exact Tooling IR#: 04

Features and Benefits

Open housings are designed to disconnect the motor from the line at the time of starting or stopping of equipment. Ideal for inertial loads and they are finger safe.

Product Specifications

90 Amp, NEMA Size 3, Open Enclosure NEMA Motor Starter -
Amperage 90
NEMA Size 3
Enclosure Type Open
Standards Met CSA LR60905 Class 3211 04; UL Listed File E78351 CCN NLDX

$2,165.19

2% Off All Online Orders
Use Code: 2%OFF

Best Price Guarantee - Email Us A Better Published Price and We'll Beat It

Schneider Electric - Contactor Auxiliary Contact Block - For Use with CR1F, TeSys D and TeSys F


Item #: 64681091
Brand: Schneider Electric
Model #: LADN11
Exact Tooling IR#: 04

Product Specifications
Contactor Accessory Type Auxiliary Contact Block
For Use With CR1F; TeSys D; TeSys F

$32.14

2% Off All Online Orders
Use Code: 2%OFF

Best Price Guarantee - Email Us A Better Published Price and We'll Beat It

Eaton Cutler-Hammer - 480 Coil VAC, 90 Amp, NEMA Size 3, Nonreversible Enclosed Enclosure NEMA Motor Starter - 50 hp at 1 Phase, 1 Enclosure Rating


Item #: 04578928
Brand: Eaton Cutler-Hammer
Model #: ECN0531CAA
Exact Tooling IR#: 04

Features and Benefits

Enclosed housings are designed to ensure that the motor is never disconnected from power during starting. Ideal for frictional loads and prevention of electrical shocks and dust.
Non-reversing starters are designed with one phase line that connects to and runs voltage through the motor. The starter is used to turn a motor on and off.
NEMA 1 refers to enclosures constructed for indoor use. They provide a degree of protection from falling and other solid objects entering the enclosure.
Product Specifications
Amperage 90
NEMA Size 3
Coil Voltage 480 VAC
Enclosure Type Enclosed
Action NonReversible
NEMA Enclosure Rating 1
Horsepower at 1 Phase 50
Overall Height (mm) 660.10
Overall Height (Decimal Inch) 25.9900
Overall Width (mm) 296.20
Overall Width (Decimal Inch) 11.6600
Overall Depth (mm) 204
Overall Depth (Decimal Inch) 8.0300
Standards Met ABS Type Approved; cUL Listed; IEC 947 Type 2; OSHPD Certified (OSP-0015-10); UL Listed

$4,428.04

2% Off All Online Orders
Use Code: 2%OFF

Best Price Guarantee - Email Us A Better Published Price and We'll Beat It

Square D - 220 Coil VAC at 50 Hz, 240 Coil VAC at 60 Hz, 18 Amp, Nonreversible Enclosed Enclosure NEMA Motor Starter - 2 hp at 1 Phase, 1 Enclosure Rating


Item #: 49789555
Brand: Square D
Model #: 8536SBG1V03E
Exact Tooling IR#: 04

Features and Benefits

Enclosed housings are designed to ensure that the motor is never disconnected from power during starting. Ideal for frictional loads and prevention of electrical shocks and dust.
Non-reversing starters are designed with one phase line that connects to and runs voltage through the motor. The starter is used to turn a motor on and off.
NEMA 1 refers to enclosures constructed for indoor use. They provide a degree of protection from falling and other solid objects entering the enclosure.
Product Specifications
Amperage 18
NEMA Size 0
Coil Voltage 220 VAC @ 50 Hz; 240 VAC @ 60 Hz
Enclosure Type Enclosed
Action NonReversible
NEMA Enclosure Rating 1
Horsepower at 1 Phase 2
Overall Height (mm) 254
Overall Height (Decimal Inch) 10
Overall Width (mm) 152
Overall Width (Decimal Inch) 6
Overall Depth (mm) 141
Overall Depth (Decimal Inch) 5.5600
Standards Met CE IEC 947-4-1; CSA File No. LR60905 Class 3211 04; UL Listed File No. E78351 CCN NLDX

$478.53

2% Off All Online Orders
Use Code: 2%OFF

Best Price Guarantee - Email Us A Better Published Price and We'll Beat It

Schneider Electric - Contactor Coil - For Use with LC1F1250, LC1F630 and TeSys F


Item #: 50936343
Brand: Schneider Electric
Model #: LX1FK415
Exact Tooling IR#: 04

Product Specifications
Contactor Accessory Type Coil
For Use With LC1F1250; LC1F630; TeSys F

$510.76

2% Off All Online Orders
Use Code: 2%OFF

Best Price Guarantee - Email Us A Better Published Price and We'll Beat It

Square D - 110 Coil VAC at 50 Hz, 120 Coil VAC at 60 Hz, 135 Amp, NEMA Size 4, Nonreversible Enclosed Enclosure NEMA Motor Starter - 3 Phase hp: 100 at 460 VAC, 100 at 575 VAC, 40 at 200 VAC, 50 at 230 VAC, 1 Enclosure Rating


Item #: 56813819
Brand: Square D
Model #: 8536SFG1V02H30S
Exact Tooling IR#: 04

Features and Benefits

Enclosed housings are designed to ensure that the motor is never disconnected from power during starting. Ideal for frictional loads and prevention of electrical shocks and dust.
Non-reversing starters are designed with one phase line that connects to and runs voltage through the motor. The starter is used to turn a motor on and off.
NEMA 1 refers to enclosures constructed for indoor use. They provide a degree of protection from falling and other solid objects entering the enclosure.
Product Specifications
Amperage 135
NEMA Size 4
Coil Voltage 110 VAC @ 50 Hz; 120 VAC @ 60 Hz
Enclosure Type Enclosed
Action NonReversible
NEMA Enclosure Rating 1
Horsepower at 3 Phase 100 @ 460 VAC; 100 @ 575 VAC; 40 @ 200 VAC; 50 @ 230 VAC
Standards Met CSA; NEMA; UL Listed

$4,784.10

2% Off All Online Orders
Use Code: 2%OFF

Best Price Guarantee - Email Us A Better Published Price and We'll Beat It

Schneider Electric - Contactor Mechanical Latch Block - For Use with LC1D115, LC1D150, LC1D80, LC1D95, LP1D80 and TeSys D


Item #: 56802846
Brand: Schneider Electric
Model #: LA6DK20B
Exact Tooling IR#: 04

Product Specifications
Contactor Accessory Type Mechanical Latch Block
For Use With LC1D115; LC1D150; LC1D80; LC1D95; LP1D80; TeSys D

$117.00

2% Off All Online Orders
Use Code: 2%OFF

Best Price Guarantee - Email Us A Better Published Price and We'll Beat It

Eaton Cutler-Hammer - 220 Coil VAC at 50 Hz, 240 Coil VAC at 60 Hz, 135 Amp, NEMA Size 4, Nonreversible Open Enclosure NEMA Motor Starter - 50 hp at 3 Phase


Item #: 04578670
Brand: Eaton Cutler-Hammer
Model #: AN16NN0B
Exact Tooling IR#: 04

Features and Benefits

Open housings are designed to disconnect the motor from the line at the time of starting or stopping of equipment. Ideal for inertial loads and they are finger safe.
Non-reversing starters are designed with one phase line that connects to and runs voltage through the motor. The starter is used to turn a motor on and off.
Open - no enclosures are starters without a protective enclosure.
Product Specifications
Amperage 135
NEMA Size 4
Coil Voltage 220 VAC @ 50 Hz; 240 VAC @ 60 Hz
Enclosure Type Open
Action NonReversible
NEMA Enclosure Rating Open - No Enclosure
Horsepower at 3 Phase 50
Overall Height (mm) 231.40
Overall Height (Decimal Inch) 9.1100
Overall Width (mm) 179.10
Overall Width (Decimal Inch) 7.0500
Overall Depth (mm) 184.20
Overall Depth (Decimal Inch) 7-1/4
Standards Met CSA Certified; UL Listed

$9,098.39

2% Off All Online Orders
Use Code: 2%OFF

Best Price Guarantee - Email Us A Better Published Price and We'll Beat It

Schneider Electric - Contactor Auxiliary Contact Block - For Use with CA2K, CA3K and TeSys K


Item #: 51274462
Brand: Schneider Electric
Model #: LA1KN40
Exact Tooling IR#: 04

Product Specifications
Contactor Accessory Type Auxiliary Contact Block
For Use With CA2K; CA3K; TeSys K

$21.86

2% Off All Online Orders
Use Code: 2%OFF

Best Price Guarantee - Email Us A Better Published Price and We'll Beat It

Square D - Contactor Jumper Strap Kit - For Use with Contactor and Starter


Item #: 69651032
Brand: Square D
Model #: 9998SO31
Exact Tooling IR#: 04

Product Specifications
Contactor Accessory Type Jumper Strap Kit
For Use With Contactor; Starter

$25.70

2% Off All Online Orders
Use Code: 2%OFF

Best Price Guarantee - Email Us A Better Published Price and We'll Beat It

Schneider Electric - Contactor Suppressor Module - For Use with LC1D400-D650, LC1D80-D95, LP1D400-D650, LP1D80 and TeSys D


Item #: 69527976
Brand: Schneider Electric
Model #: LA4DC3U
Exact Tooling IR#: 04

Product Specifications
Contactor Accessory Type Suppressor Module
For Use With LC1D400-D650; LC1D80-D95; LP1D400-D650; LP1D80; TeSys D

$32.25

2% Off All Online Orders
Use Code: 2%OFF

Best Price Guarantee - Email Us A Better Published Price and We'll Beat It

Schneider Electric - Contactor Suppressor Module - For Use with LC1D40A-D65A, LC1DT60A-DT80A and TeSys D


Item #: 69664068
Brand: Schneider Electric
Model #: LAD4V3U
Exact Tooling IR#: 04

Product Specifications
Contactor Accessory Type Suppressor Module
For Use With LC1D40A-D65A; LC1DT60A-DT80A; TeSys D

$32.49

2% Off All Online Orders
Use Code: 2%OFF

Best Price Guarantee - Email Us A Better Published Price and We'll Beat It

Square D - 220 Coil VAC at 50 Hz, 240 Coil VAC at 60 Hz, 45 Amp, NEMA Size 2, Nonreversible Enclosed Enclosure NEMA Motor Starter - 3 Phase hp: 10 at 200 VAC, 15 at 230 VAC, 25 at 460 VAC, 25 at 575 VAC, 1 Enclosure Rating


Item #: 56814767
Brand: Square D
Model #: 8536SDG1V03S
Exact Tooling IR#: 04

Features and Benefits

Enclosed housings are designed to ensure that the motor is never disconnected from power during starting. Ideal for frictional loads and prevention of electrical shocks and dust.
Non-reversing starters are designed with one phase line that connects to and runs voltage through the motor. The starter is used to turn a motor on and off.
NEMA 1 refers to enclosures constructed for indoor use. They provide a degree of protection from falling and other solid objects entering the enclosure.
Product Specifications
Amperage 45
NEMA Size 2
Coil Voltage 220 VAC @ 50 Hz; 240 VAC @ 60 Hz
Enclosure Type Enclosed
Action NonReversible
NEMA Enclosure Rating 1
Horsepower at 3 Phase 10 @ 200 VAC; 15 @ 230 VAC; 25 @ 460 VAC; 25 @ 575 VAC
Standards Met CSA; NEMA; RoHS Compliant; UL Listed

$1,755.18

2% Off All Online Orders
Use Code: 2%OFF

Best Price Guarantee - Email Us A Better Published Price and We'll Beat It

Eaton Cutler-Hammer - 208 Coil VAC, 90 Amp, NEMA Size 3, Nonreversible Enclosed Enclosure NEMA Motor Starter - 25 hp at 1 Phase, 1 Enclosure Rating


Item #: 04578936
Brand: Eaton Cutler-Hammer
Model #: ECN0531EAA
Exact Tooling IR#: 04

Features and Benefits

Enclosed housings are designed to ensure that the motor is never disconnected from power during starting. Ideal for frictional loads and prevention of electrical shocks and dust.
Non-reversing starters are designed with one phase line that connects to and runs voltage through the motor. The starter is used to turn a motor on and off.
NEMA 1 refers to enclosures constructed for indoor use. They provide a degree of protection from falling and other solid objects entering the enclosure.
Product Specifications
Amperage 90
NEMA Size 3
Coil Voltage 208 VAC
Enclosure Type Enclosed
Action NonReversible
NEMA Enclosure Rating 1
Horsepower at 1 Phase 25
Overall Height (mm) 660.10
Overall Height (Decimal Inch) 25.9900
Overall Width (mm) 296.20
Overall Width (Decimal Inch) 11.6600
Overall Depth (mm) 204
Overall Depth (Decimal Inch) 8.0300
Standards Met ABS Type Approved; cUL Listed; IEC 947 Type 2; OSHPD Certified (OSP-0015-10); UL Listed

$4,428.04

2% Off All Online Orders
Use Code: 2%OFF

Best Price Guarantee - Email Us A Better Published Price and We'll Beat It